Screw ring

The screw ring is provided with a saw tooth thread. Maintain the correct orientation when remounting the cell. If the ring appears to stall when tightening, DO NOT apply additional force but flip the ring upside down and try again. The screw ring shall be tightened with defined torque, depending on the centerpiece material. A torque stand is required for this procedure.

Cap with saw tooth thread 813 Cap with saw tooth thread

Screw ring washer

Screw ring washer 8192 Screw ring washer

Window holder

Window holders are available in two variants: for housings with metric threaded filling holes and for such with imperial threaded filling holes. Furthermore, special holders are provided for use with interference optics only. These considerably enhance the quality of detection, but they cannot be used with absorbance optics. Read more about the benefits of interference window holders here. [Link zur Seite Interferenzfensterhalter aus der alten Website.] Interference window holders are only used for the top side; on the bottom side, there will always be window holders with regular cutouts,

Window holder for housings with metric filling hole threads 812 Window holder for housings
Window holder for housings with imperial filling hole threads 812-IM
Interference window holder for housings with metric filling hole threads 812-IF Interference window holder for housings
Interference window holder for housings with imperial filling hole threads 812-II

Window gaskets

Window gaskets 8191 Window gaskets

Window liners

Window liners 8193 Window liners

Windows

Cell windows are provided in quartz and sapphire. Sapphire windows are recommended for use with interference optics. Quartz windows were used for maximum transmittance in the UV range, but modern sapphire windows are of equal quality. They have the benefit of higher stability and will not “crack” as easily.

Quartz window 835 Cell window
Sapphire window 834

Centerpieces

Centerpieces made of titanium provide resistance towards most solvents (acidic, basic, organic) and towards rotational speeds up to 60 krpm. They require double sector gaskets as consumables with every run. Epoxy centerpieces are sensitive towards organic solvents but require no gaskets.

Titanium centerpiece, 1.5 mm pathlength 810-01 Titanium centerpiece, 1.5 mm pathlength
Titanium centerpiece, 3 mm pathlength 810-03 Titanium centerpiece, 3 mm pathlength
Titanium centerpiece, 6 mm pathlength 810-06 Titanium centerpiece, 6 mm pathlength
Titanium centerpiece, 12 mm pathlength 810-12 Titanium centerpiece, 12 mm pathlength
Titanium centerpiece, 20 mm pathlength 810-20 Titanium centerpiece, 20 mm pathlength
Epoxy centerpiece, 12 mm pathlength, 50 krpm 808-12 Epoxy centerpiece, 12 mm pathlength, 50 krpm
Epoxy centerpiece, 3 mm pathlength, 50 krpm 808-03 Epoxy centerpiece, 3 mm pathlength, 50 krpm
Epoxy centerpiece, 12 mm pathlength, 60 krpm 809-12 Epoxy centerpiece, 12 mm pathlength, 60 krpm
Epoxy centerpiece, 3 mm pathlength, 60 krpm 809-03 Epoxy centerpiece, 3 mm pathlength, 60 krpm

Special Centerpieces: Meniscus Matching

Meniscus matching centerpieces are used to ensure that the meniscus location of the fluid in the reference channel, (left side) and sample channel (right side) are identical.

This procedure offers significant advantages for the AUC user: Using Rayleigh interference detection, perfectly matched menisci are required to avoid signal offsets from solvent/buffer components in both sectors, resulting in superposition onto the analyte signal. In doing so, the data evaluation is enhanced by reducing efforts to account for such signal offsets employing dedicated data algorithms.

Be sure to follow the instructions for working with meniscus matching centerpieces.

Titanium centerpiece, Meniscus matching version, all pathlengths 901-TI Titanium centerpiece, Meniscus matching version, all pathlengths

Spacers

Spacers are used to fit short centerpieces into standard 12 mm housings. This will shift the centerpieces out of the 2/3 plane optimal for interference detection. For imperial threaded housings, only available in 12 mm layout, this drawback cannot be avoided. Metric threaded housings are available for all optical pathlengths, providing optical geometry, eliminating this limitation.

Spacer for 3 mm centerpieces in 12 mm housings 814-03 Spacer for 3 mm centerpieces in 12 mm housings
Spacer for 1.5 mm centerpieces in 12 mm housings 814-01 Spacer for 1.5 mm centerpieces in 12 mm housings
Spacer for 3 mm centerpieces in 12 mm FDS housings 814-FD Spacer for 3 mm centerpieces in 12 mm FDS housings

Housings

Housing for 1.5 mm centerpieces, metric thread 811-01 Housing
Housing for 3 mm centerpieces, metric thread 811-03
Housing for 6 mm centerpieces, metric thread 811-06
Housing for 12 mm centerpieces, metric thread 811-12
Housing for 20 mm centerpieces, metric thread 811-20
Housing for 3 mm centerpieces, metric thread, FDS 811-FD
Housing for 3 mm centerpieces, imperial thread, FDS 811-FI
Housing for 12 mm centerpieces, imperial thread1 811-IM

1 Can be used for 1.5 and 3 mm centerpieces with corresponding spacers.

Filling hole plugs

Filling hole plugs are available with metric threads (for metric threaded housings) and imperial threads (for imperial threaded housings). They are distinguishable by their color (steel for metric, brass for imperial) and socket (slit for metric, hex for imperial). Note that for housings of other makes than Nanolytics Instruments, imperial threaded screws are required, and those traditionally offered feature slit screws as well.

It is recommended to use an appropriate screwdriver for slit drive screws made by Nanolytics Instruments. It provides perfect fit, with optimum torque transfer and avoiding wearing of the slit.
Screwdrivers with torque control are available for both types.
Gaskets for filling hole screws are available as consumables.

Filling hole plugs for imperial threaded housings (hex socket) 816-IM Filling hole plugs for imperial threaded housings (hex socket)
Filling hole plugs for metric threaded housings (slit socket) 816-MT Filling hole plugs for metric threaded housings (slit socket)

Complete Cell Assemblies

Ordering cells as complete assemblies does not provide a financial benefit; it is for simplification only. However, when complete assemblies with windows are ordered, they are tested for leakages prior to shipping.

Cell Assemblies with Titanium Centerpieces (Metric)

Measurement cell with 1.5 mm titanium centerpiece with windows 800-01 Measuring cell with 1.5 mm titanium centerpiece
Measurement cell with 1.5 mm titanium centerpiece without windows 801-01
Measurement cell with 3 mm titanium centerpiece with windows 800-03 Measuring cell with 3 mm titanium centerpiece
Measurement cell with 3 mm titanium centerpiece without windows 801-03
Measurement cell with 6 mm titanium centerpiece with windows 800-06 Measuring cell with 6 mm titanium centerpiece
Measurement cell with 6 mm titanium centerpiece without windows 801-06
Measurement cell with 12 mm titanium centerpiece with windows 800-12 Measuring cell with 12 mm titanium centerpiece
Measurement cell with 12 mm titanium centerpiece without windows 801-12
Measurement cell with 20 mm titanium centerpiece with windows 800-20 Measuring cell with 20 mm titanium centerpiece
Measurement cell with 20 mm titanium centerpiece without windows 801-20

Cell Assemblies with Epoxy Centerpieces (Imperial)

Measurement cell with Spin50 12 mm Epoxy centerpiece (with windows) 803-12
Measurement cell with Spin50 12 mm Epoxy centerpiece (without windows) 802-12
Measurement cell with Spin50 3 mm Epoxy centerpiece and spacers (with windows) 803-03
Measurement cell with Spin50 3 mm Epoxy centerpiece and spacers (without windows) 802-03
Measurement cell with Spin60 12 mm Epoxy centerpiece (with windows) 805-12
Measurement cell with Spin60 12 mm Epoxy centerpiece (without windows) 804-12
Measurement cell with Spin60 3 mm Epoxy centerpiece and spacers (with windows) 805-03
Measurement cell with Spin60 3 mm Epoxy centerpiece and spacers (without windows) 804-03

Cell Assemblies with Titanium Centerpieces (Imperial)

Measurement cell with 12 mm titanium centerpiece (with windows) 807-12
Measurement cell with 12 mm titanium centerpiece (without windows) 806-12
Measurement cell with 3 mm titanium centerpiece and spacers (with windows) 807-03
Measurement cell with 3 mm titanium centerpiece and spacers (without windows) 806-03

Cell Assemblies for Fluorescence Detection (Imperial)

Measurement cell with 3 mm titanium centerpiece for FDS (with windows) 841-TI
Measurement cell with 3 mm titanium centerpiece for FDS (without windows) 840-TI
Measurement cell with 3 mm epoxy centerpiece for FDS (with windows) 841-EP
Measurement cell with 3 mm epoxy centerpiece for FDS (without windows) 840-EP

For quotations, purchase orders, questions and further information contact sales@nanolytics-instruments.com.